Filter

Support
Luxor CUBE

CUBE Models

Tabs

Read Article

The Luxor CUBE allows the Luxor to control, zone, and dim lighting fixtures and other devices that don’t have built-in FX technology. Install the CUBE in-line prior to the fixtures or devices you wish to control as a zone. When that zone (Group) is activated by the Luxor, the light on the Cube LED will illuminate along with all fixtures/devices inline and will initiate/dim according to the commands of the Luxor.

Three Luxor CUBE Models available:
Low Voltage (LCM-LV)
  • Add zoning and dimming to AC dimmable LEDs (Diagram A)
  • Luxor will power the dimmable LEDs, but an alternate power source is required for incandescent lamps (Diagram B)
  • Do not exceed 60 watts
  • In/Out Voltage - The voltage coming in is the same voltage on the output side (e.g.,15 VAC in - 15 VAC Out).

CAUTION

  • Attach only lamps to the output of the LV CUBE.
  • Attach only dimmable lamps to the output.
  • Do not use the LUXOR as both power and control if an incandescent fixture is attached to the CUBE's output.
  • Do not apply more than 15VAC to the input power leads.
  • Do not attach more than 60W of lamps to the output of the LV CUBE.
  • Use only watertight connectors in wet environments.
High Voltage (LCM- HV)
  • Add zoning and dimming to incandescent and AC dimmable LED fixtures.
  • Do not exceed 400 watts

CAUTION

  • Attach only lamps to the output of the HV CUBE (no motors, transformers or other non-lamp loads).
  • Do not attach the output of the HV CUBE to a non-dimmable lamp.
  • Do not attach more than 400watts of lamps to the output.
  • Do not short the output.
  • Use only forward phase-cut dimmable lamps.
  • Do not apply 230 ,240, or 277VAC to the input.
  • Do not install the CUBE such that its output is connected to a standard wall outlet.
  • Do not forget to attached the green wire to ground.
  • Install inside a junction box according to NEC guidelines.
Relay and 0-10V (LCM-RLY-010V)
  • Control via relay or 0-10V dimming

CAUTION

  • Do not attach the 0-10V output of the CUBE to anything except a 0-10V input dimmable power supply.
  • Do not use to switch a load greater than 250VAC.
  • Do not use to switch a load greater than 5A.
  • Do not use to switch a load that requires a horsepower-rated relay.
Rate this Article: 
0
No votes yet

Was this article helpful? Yes | No