The SURGE MOD is designed to provide two additional layers of surge protection to any low-voltage LED fixture. The module should be used in areas prone to frequent surge events (e.g., lightning storms). The Surge Module is designed to be buried directly in-line with low voltage LED fixtures. A viewing window located on the top of the product provides contractors with a visual indication that a surge event has occurred and that the module should be replaced.
Specifications
| Model No. | Operating Voltage | ln | MCOV |
|---|---|---|---|
| Surge-Mod | 15 VAC (50/60 Hz) | 1kA | 15 VAC |
In - Nominal Discharge Current
MCOV - Maximum Continuous Operating Voltage
Surge Indicator
Wiring Diagram
Install the surge module in line every fifty feet or every five fixtures, whichever comes first.