Luxor Linking allows for a single point of control on sites requiring multiple Luxor ZD or Luxor ZDC controllers. Linking sites consists of a primary and one or more satellite Luxor controllers connected by a Cat5/5e/6 cable. Sites are limited to nine satellite controllers to every one primary unit and/or 3,000 feet between the primary and the farthest satellite controller.

NOTE: Making your own Ethernet Cat cable is recommended to be done by a qualified technician only.

Firmware Requirements:

LUXOR FACEPACK CHASSIS
ZD v0.167 v0.24
ZDC v0.305 v0.24
LSAT v0.24

NOTE: Firmware files and instructions for updating, please visit: Updating the Firmware

 

Hardware Requirements:

PRIMARY CONTROLLER

  • Luxor ZD or Luxor ZDC - Manufacturing datecode AUG16 or later

SATELLITE CONTROLLER

  • LSAT300M or LSAT300SS
  • Luxor ZD or Luxor ZDC - Manufacturing datecode AUG16 or later can be retrofitted into a satellite controller by removing Facepack and updating chassis firmware

COMMUNICATION CABLE

  • Direct burial Cat5/5e/6 cable (straight)

NOTE: Prior to running a Linking system, verify Primary and Satellite Luxors have the latest version of Facepack (Primary controller only) and chassis (Primary and Satellite) linking firmware.