Luxor Linking allows for a single point of control on sites requiring multiple Luxor ZD or Luxor ZDC controllers. Linking sites consists of a primary and one or more satellite Luxor controllers connected by a Cat5/5e/6 cable. Sites are limited to nine satellite controllers to every one primary unit and/or 3,000 feet between the primary and the farthest satellite controller.
NOTE: Making your own Ethernet Cat cable is recommended to be done by a qualified technician only.
Firmware Requirements:
| LUXOR | FACEPACK | CHASSIS |
|---|---|---|
| ZD | v0.167 | v0.24 |
| ZDC | v0.305 | v0.24 |
| LSAT | - | v0.24 |
NOTE: Firmware files and instructions for updating, please visit: Updating the Firmware
Hardware Requirements:
PRIMARY CONTROLLER
- Luxor ZD or Luxor ZDC - Manufacturing datecode AUG16 or later
SATELLITE CONTROLLER
- LSAT300M or LSAT300SS
- Luxor ZD or Luxor ZDC - Manufacturing datecode AUG16 or later can be retrofitted into a satellite controller by removing Facepack and updating chassis firmware
COMMUNICATION CABLE
- Direct burial Cat5/5e/6 cable (straight)
NOTE: Prior to running a Linking system, verify Primary and Satellite Luxors have the latest version of Facepack (Primary controller only) and chassis (Primary and Satellite) linking firmware.
Still need help? We're here.
Tell us what you need support with and we'll find the best solution for you.