Install pressure treated 4" x 4" x 36" (min) post in concrete footing. Install single anchor screw 11⁄2"–2" below the top of post. Place transformer on screw. Place 9" torpedo level on top of transformer and level transformer. Once level, secure transformer to post by installing 1 or 2 screws on the bottom-mounting bracket.
All LX Series Transformers come equipped with a 3 foot, 12 gauge, 3-prong electrical power cord to be used in conjunction with a 120 volt class A type ground fault circuit interrupter electrical receptacle. The LX power cord should be used only in conjunction with a 120 volt receptacle. Do not use an extension cord with a cord connected landscape lighting system.
For hard wire installations, remove the LX power cord and wire the transformer in compliance with local electrical building codes. It is recommended that the electrician install a dedicated 15 or 20 amp circuit breaker in the electrical panel.
A - Side View
B - Front View
- 1½" conduit
- 4 x 4 post
- Concrete footing
- 12" minimum
- Mounting brackets