Filter

Support
Line-Voltage Lights

A-CT4 - Repair

Tabs

Read Article

Caution and Safety Instructions

  • Qualified personnel must install and/or service product in a manner consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and/or all local and provincial codes.
  • Follow all product label information and installation instructions.
  • Turn off power at fuse or circuit breaker before installation or servicing.
  • The use of damaged components may cause an unsafe condition and void product warranty.
  • Do not block light emanating from product in whole or part.
  • Never operate the luminaire with missing or damaged lens. Clean lens on a regular basis.
  • Entire luminaire may become extremely hot. Do not touch hot lens or luminaire body. Do not touch the light source at any time.
  • Keep all O-rings and sealing surfaces clean during installation and servicing; failure to do this may lead to premature failure of the product.
Step 1

Remove the cap by unfastening the 6-32 x 1/ 2" (13 mm) screw using a 7/64" Allen key. Then lift the cap outward. Avoid using metal tools while lifting the cap to protect the power coat finish.

Step 2

Twist the reflector optic counterclockwise and pull outward to remove.

Step 3

Unfasten the three LED module screws using a Phillips #1 screwdriver. Remove the reflector adapter ring and LED module.

Rate this Article: 
0
No votes yet

Was this article helpful? Yes | No